In nonlinear mathematical models of the arterial circulation, the viscoelasticity of the vessel walls has generally been neglected or only taken into account in a highly approximate manner. A new method is proposed to simulate the nonlinear viscoelastic properties of the wall material with the aid of a convolution integral of the creep function and the pressure history. With this simulation it is possible to properly describe the measured characteristics of arterial viscoelasticity. Moreover, it is utilized in a mathematical model of arterial pulse propagation to study the influence of the internal wall friction on the shape, amplitude and mean value of pressure and flow pulses. The corresponding predictions are in much better agreement with in-vivo measurements, especially for the distal part of the circulation, than those obtained without viscoelasticity.
Skip Nav Destination
Article navigation
November 1980
Research Papers
A Viscoelastic Model for Use in Predicting Arterial Pulse Waves
R. Holenstein,
R. Holenstein
Institute of Biomedical Engineering of the University of Zurich and the Swiss Federal Institute of Technology, Zurich, Switzerland
Search for other works by this author on:
P. Niederer,
P. Niederer
Institute of Biomedical Engineering of the University of Zurich and the Swiss Federal Institute of Technology, Zurich, Switzerland
Search for other works by this author on:
M. Anliker
M. Anliker
Institute of Biomedical Engineering of the University of Zurich and the Swiss Federal Institute of Technology, Zurich, Switzerland
Search for other works by this author on:
R. Holenstein
Institute of Biomedical Engineering of the University of Zurich and the Swiss Federal Institute of Technology, Zurich, Switzerland
P. Niederer
Institute of Biomedical Engineering of the University of Zurich and the Swiss Federal Institute of Technology, Zurich, Switzerland
M. Anliker
Institute of Biomedical Engineering of the University of Zurich and the Swiss Federal Institute of Technology, Zurich, Switzerland
J Biomech Eng. Nov 1980, 102(4): 318-325 (8 pages)
Published Online: November 1, 1980
Article history
Received:
August 11, 1980
Online:
June 15, 2009
Article
Article discussed|
View article
Connected Content
Citation
Holenstein, R., Niederer, P., and Anliker, M. (November 1, 1980). "A Viscoelastic Model for Use in Predicting Arterial Pulse Waves." ASME. J Biomech Eng. November 1980; 102(4): 318–325. https://doi.org/10.1115/1.3138229
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
A Numerical Solution for Quasistatic Viscoelastic Frictional Contact Problems
J. Tribol (January,2008)
An Analytical Model for Time-Dependent Shearing Deformation in Area-Array Interconnects
J. Electron. Packag (December,2000)
Wave Propagation in Thin-Walled Aortic Analogues
J. Fluids Eng (February,2010)
Related Proceedings Papers
Related Chapters
Non-Invasive Method for Measuring Local Viscoelasticity of Arterial Vessels
Biomedical Applications of Vibration and Acoustics in Imaging and Characterizations
Openings
Guidebook for the Design of ASME Section VIII Pressure Vessels
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range