Since the electrogoniometric method has been justified for the measurement of lower extremity joint motion, a similar device is developed for the measurement of elbow joint and forearm rotations. In this design, the axis of forearm rotation coincides with the anatomical axis which eliminates the cross talk existing in the regular triaxial goniometer. Although the axis of abduction-adduction is still offset from the elbow joint, special linkage arrangement was used to obtain equivalent motion. Experimental method was used to validate the accuracy of the device and model simulation was performed to emphasize the importance of accurate placement of the instrument on test subjects. Application of the present apparatus to normal subjects was studied to illustrate the range of elbow motion required in performing normal activities of daily living. This device is currently used in the functional evaluation of patients with elbow and forearm problems.
Skip Nav Destination
Article navigation
November 1980
Research Papers
Electrogoniometer for the Measurement of Human Elbow Joint Rotation
E. Y. Chao,
E. Y. Chao
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
Search for other works by this author on:
K. N. An,
K. N. An
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
Search for other works by this author on:
L. J. Askew,
L. J. Askew
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
Search for other works by this author on:
B. F. Morrey
B. F. Morrey
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
Search for other works by this author on:
E. Y. Chao
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
K. N. An
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
L. J. Askew
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
B. F. Morrey
Orthopedic Biomechanics Laboratory, Mayo Clinic / Mayo Foundation, Rochester, Minn. 55901
J Biomech Eng. Nov 1980, 102(4): 301-310 (10 pages)
Published Online: November 1, 1980
Article history
Received:
December 8, 1979
Revised:
August 11, 1980
Online:
June 15, 2009
Citation
Chao, E. Y., An, K. N., Askew, L. J., and Morrey, B. F. (November 1, 1980). "Electrogoniometer for the Measurement of Human Elbow Joint Rotation." ASME. J Biomech Eng. November 1980; 102(4): 301–310. https://doi.org/10.1115/1.3138227
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
Geometric Method of Spatial Linkages Synthesis for Function Generation With Three Finite Positions
J. Mech. Des (August,2018)
An Application of Yaglom's Geometric Algebra to Kinematic Synthesis of Linkages for Prescribed Planar Motion of Oriented Lines
J. Mech. Des (March,2018)
On Realization of Spherical Joints In RSSR Mechanisms
J. Mech. Des (September,2005)
Analysis of Rotational Precision for an Isosceles-Trapezoidal Flexural Pivot
J. Mech. Des (May,2008)
Related Proceedings Papers
Related Chapters
Design and Analysis of a Double-Half-Revolution Mechanism Exploration Rover
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)
Study on the Simulation System of Cam-Linkage Mechanisms Based on the Simulink Software
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Key Technologies of Instrument Simulation in the Virtual Maintenance System
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)